Version 6.57.8130 Build 8130 23rd
September 2007
|
- Added import for analogue data in Vicon .csv files
- Improvements to DataLogger maximum sampling rate in certain
scenarios. When using a single channel pair (i.e. channels 1&5
or 2&6, etc) the maximum sampling rate permitted is now 3500Hz
(previously it was 5500/2 = 2750Hz). More info...
In other scenarios, the
maximum rate remains unchanged with all 8 channels at 1000Hz
each or a total of 5500/num channels when using 1-7 channels.
Also corrected a bug which allowed invalid sample rates for the
logger to be specified where the total rate exceeded the 5500
limit of the logger but fell below the 8000 limit possible when
using all 8 channels. The profiles now correctly block invalid
total rates above 5500 except when using all 8 channels at
1000Hz each (8000Hz) or the new special 2 channel paired mode at
3500Hz each (7000 Hz).
- Corrected channel indexes in exported ascii files when using
non-sequential channels.
|
|
Version 6.56.8095 Build 8095 09th
August 2007
|
- Added transducer models for use with Biodex equipment
(Torque, Velocity & Position)
- Added transducer model for strain gauge goniometers (Penny &
Giles goniometers)
- Added support for high capacity batteries in the DataLogger.
|
|
Version 6.55.8090 Build 8090 23rd
July 2007
|
- Added support for Amplicon PCI260+ A/D Card.
- Added trigger start from MCC DAS16/12.
- Corrected a timeout problem when detecting the DataLogger
port automatically which affected customers with Bluetooth or
other types of virtual serial port which don't respond when
queried.
- Test Session no longer always displays the welcome page (can
be disabled) and remembers last used settings.
|
|
Version 6.54.8050 Build 8050 10th
September 2006
|
- Added Zoom To... function which allows you to quickly zoom
the charts to precise positions.
|
|
Version 6.53.8020 Build 8020 05th
April 2006
|
- Corrected incorrect channel indexing issues with Amplicon
PCI260.
- Corrected incorrect channel reference on live preview when
using inactive channels.
|
|
Version 6.52.8000 Build 8000 01st
March 2006
|
- Correct some hardware profile indexing issues concerning not
connected channels.
|
|
Version 6.51.7920 Build 7920 22nd
December 2005
|
- Added Filtering support. Data can now be filtered by a
moving point average or Finite Impulse Response (FIR) filter
providing a user-definable highpass, lowpass and bandpass
filter.
|
|
Version 6.50.7830 Build 7830 6th
December 2005
|
- New AutoSync feature allows video to be semi-automatically
synchronised with data. Supports DataLogger Event Marker Remote
(DL-EMR).
|
|
Version 6.49.7790 Build 7790 14th
October 2005
|
- Improved memory handling for large files.
- Corrected live preview problems for DAS16 series at slow
acquisition speeds.
- Resolved an installation problem on AMD Turion 64 machines
where the Aladdin Device Driver could fail to install,
generating the error 'Failed to start a service in the Service
Control Manager Database0x2008007 0x20007 0x0'
|
|
Version 6.48.7570 Build 7570 02nd
August 2005
|
- New feature: Video support. Video files can be displayed and
synchronised alongside captured data signals. (Requires
DirectX 9.0+ runtime).
|
|
Version 6.47.7300 Build 7300 16th
June 2005
|
- Large DataLogger datasets are now imported much faster.
- Changes to the way the DataLogger is programmed. After
installation, please be sure to re-program your logger before
collecting data to avoid any incompatabilities.
- After DataLogger programming MyoDat will estimate the
maximum recording time given the chosen hardware profile and
available memory.
|
|
Version 6.46.7220 Build 7220 18th May 2005
|
- Printed axis scales are now rendered correctly on all
printers.
- Print Preview of charts corrected.
- Chart backgrounds are no longer printed.
- Last used printer settings are now stored and used
automatically.
|
|
Version 6.45.7070 Build 7070 22nd Mar 2005
|
- Extending analysis cropping capabilities.
- Improved default analysis layout.
|
|
Version 6.44.7020 Build 7020 1st Mar 2005
|
- Corrected error 861 'The acquisition source of this data
file could not be properly determined.' when analysing imported
.ANC files [CASE: MyoDat050301-2].
- Extended DataLogger menu to provide ability to format new
memory cards.
|
|
Version 6.43.6690 Build 6690 22nd Feb 2005
|
- Fixed memory related issues when loading long files.
- Vastly improved loading speed of long data files. Progress
feedback on the operation is also now provided.
- New area selection in chart analysis. Choose the selection
tool from the toolbar then drag select desired area. Right click
to crop / delete the selected data points as appropriate.
- Improved drawing speed when analysis charts are zoomed,
particularly with large datasets.
|
|
Version 6.42.6470 Build 6470 24th Jan 2005
|
- Fixed division by zero error which occurred when choosing FFT/PSD
analysis from the analysis toolbar of a test already open for
analysis.
- Corrected a problem which caused program menus to be displayed
erroneously in French, instead of English, on Windows 95/98/ME
systems. [CASE: WinCAS041214-1]
- List all Patients/Subjects now correctly displays all
patients/subjects. Previously not all records were being listed
correctly [CASE: WinCAS041221-1]
- Extended patient/subject search to permit the searching by
gender, dominant side and status.
|
|
Version 6.41.6450 Build 6450 13th Dec 2004
|
- Fixed instabilities in the analysis toolbar which caused the
application to crash when switching between differing modes of
analysis.
|
|
Version 6.40.6400 Build 6400 5th Nov 2004
|
- New formula editor in charts. Type '=' into a series offset
value.
|
- Using the formula editor to change the
series unit type is currently not supported. The data will be valid
however the series will be labelled and processed incorrectly.
|
Version 6.39.6370 Build 6370 29th Oct 2004
|
- Corrected importing of DataLogger data which could omit the last
channel in certain configurations.
|
|
Version 6.38.6350 Build 6350 22nd Oct 2004 |
- Fixed DataLogger voltage scaling issues.
- Deleted subjects and tests are now removed from the recent
subjects and recent tests menus.
|
|
Version 6.37.6300 Build 6300 6th Oct 2004
|
- Fixed a hang which may occur when opening the analysis windows.
|
Some instabilities remain in the new analysis toolbar
which can cause the application to crash when switching between
differing modes of analysis.
|
Version 6.36.6240 Build 6240 17th Sep 2004
|
- New offset adjustment allows you to manually offset transducers
or analysis results. This may be useful to manually remove any
offsets which could not be removed during the initial setup of the
transducers. Additionally the x-axis can also be offset which may
aid comparison - however generally it is preferable to use the axes
lock functions of the charts for this purpose.
|
Instabilities in the new analysis
toolbar can cause the application to crash when switching between
differing modes of analysis. This will be resolved in the next
release.
|
Version 6.35.6200 Build 6200 15th Sep 2004
|
- It is now possible to add/rename/delete test categories directly
on the test information form after performing a measurement.
- Correct sampling rate issues with DataLogger. Requested sampling
rate was not being set correctly for new models.
- MyoDat no longer stops responding whilst programming the
DataLogger.
- Enabled analysis toolbar from the analysis charts. It is now
possible to quickly switch between analysis modes from the toolbar.
Data with identical axes appears in the same chart automatically and
is therefore easy to overlay.
|
|
Version 6.34.6000 Build 6000 28th Jul 2004
|
- Improvements to the auto scaling of analysis charts.
- New test no longer prompts for normal or DataLogger. This is
determined by the acquisition source in the hardware profile.
DataLogger data is now imported via the Import button as documented.
- New option during installation sets the default acquisition
source and customises the welcome wizard accordingly.
- Subject medication and intervention lists can now be populated
with new items.
- It is now possible to add/rename/delete note categories directly
on the subject clinical information tab.
|
|
Version 6.33.5880 Build 5880 9th Jun 2004
|
- Fixed an exception occurring during the DataLogger live preview.
|
|
Version 6.32.5850 Build 5850 4th Jun 2004
|
- Easier comparative analysis feature allows you to select tests
in different subjects. Then analyse them simultaneously by simply
holding the Ctrl key when choosing your method of analysis.
- New analysis toolbar provides rapid access to various analysis
functions.
- Popup explorer window upon inserting DataLogger's memory card is
now blocked if you are on the DataLogger import page.
- Fixed a rare intermittent exception which could occur when
saving a subject record.
|
|
Version 6.31.5650 Build 5650 6th May 2004
|
- Fixed problem with acquisition at low speeds for the DAS16/12.
|
|
Version 6.30.5620 Build 5620 15th March 2004
|
- Fixed DataLogger problem whereby unit could not connect if it
was connected on serial port with a high COM port number on Windows
XP.
- DataLogger now supports 1GB MIE MMCs.
|
|
Version 6.29.5600 Build 5600 4th February 2004
|
- Several fixes to the Hardware Profile Wizard. Custom placements
can now be entered by clicking on the Custom button. Accelerometer
transducers no longer prompt you to select a muscle for placement,
instead you are prompted for a custom location. Additionally the
appropriate joint name is now displayed when hovering over joint
placements.
- Added support for importing Ancillary Files (.anc)
|
|
Version 6.28.5360 Build 5360 28th November 2003
|
- Added Fatigue Analysis - see updated manual for usage
instructions.
- Updated Encyclopaedia.
- Minor improvements to the Hardware Profile Wizard. Apply button
is now enabled when changes to the profile are made via the
step-by-step wizard. User is now warned changes will be lost upon
closing dialog without having saved. Improved validation of profile
configuration to selected hardware acquisition source/device.
|
|
Version 6.27.5280 Build 5280 19th November 2003
|
- Added facilities for programming our new 8 Channel
Data Logger.
|
|
Version 6.26.5150 Build 5150 14th November 2003
|
- Fixed scales for final analysis of DAS16/12 data.
- Fixed auto-zero for DAS16/12.
- Updates to database ready for new 'Event Markers' feature
- Minor improvements 'Live Preview' now defaults to white
background for a cleaner look.
|
|
Version 6.25.4900 Build 4900 BETA 21st October 2003
|
- Fixed live preview for DAS16/12.
- Fixed DAS16/12 not being detected as a 'Any Detected Source'.
- Fixed numerous sampling rate problems with DAS16/12. Sampling
rate could be much higher than requested causing the rate to be out
of range generating the error 'Invalid sampling rate'.
- Fixed 'noisy' data for DAS16/12's not configured correctly
during installation - correct configuration is now set automatically
by MyoDat.
- Time axis in analysis for DAS16/12 now correct (relates to
sampling rate problem).
- Fixed export to Excel 'Invalid bracketing of xxx' error.
- Fixed erroneous error when exporting data from analysis charts.
If you chose a filename without extension MyoDat would report 'You
must select the type of file to be saved.' despite a valid file type
being chosen in the 'Save As' field.
|
Accelerometer transducer incorrectly prompts for a muscle
placement in Hardware Profile Wizard.
Problems with slow acquisition speeds on DAS16/12 - use
sampling rate of 2500 or higher.
Scales incorrect in final analysis for DAS16/12.
|
Version 6.24.4640 Build 4640 1st October 2003
|
- Added support for Measurement Computing PCMCIA DAS16/12
acquisition card. Updated CD to include appropriate drivers.
- Fixed a small problem with retaken tests which caused the same
test to be appear multiple times in the analysis window.
- Updated manual (issue 4).
|
|
Version 6.23.4440 Build 4440 16th September 2003
|
- Implemented printing support for the analysis graphs.
- Minor improvements and fixes to the Test Session Wizard.
- Added elapsed and remaining time indicators during acquisition.
- Several minor fixes to the Hardware Profile Dialog.
- Test Info form is now resizable.
- Minor fixes and improvements to the toolbars. A drawing problem
previously meant the borders of each toolbar may appear corrupt.
Additionally it is now possible to customise the toolbars.
|
Printed fonts are too small on some printer models.
|
Version 6.22.4100 Build 4100 14th May 2003
|
- Hardware Profile Dialog now correctly assigns transducer
selection via step-by-step interface.
- Added channel confirmation page to the Hardware Profile
step-by-step interface.
- Installation script updated to register components used during
the FFT/PSD analysis, resolving the error:
- Corrected a problem which would cause the 'Database Backup
Overdue' prompt to be displayed repeatedly regardless of the user's
postponements.
- Install script updated to allow updating of older versions
without manually uninstalling old version beforehand - see known
problems.
|
- When updating an existing installation the existing destination
and database location are not retained by the installer. Users with
non-default locations must select their old locations as they did
during installation originally. This problem does not affect users
upgrading via small patch files.
|
Version 6.21.4000 Build 4000 26th Apr 2003
|
- Added facility to delete a subject from the database.
- All legacy references to patients have been renamed to subjects.
- Additional muscle images added to the hardware profile channel
pages.
|
|
Version 6.20.3940 Build 3940 13th Apr 2003
|
- Correct minor problem with items appearing disabled in the
analysis popup menu when they should be enabled.
- Corrected an overflow exception during FFT/PSD analysis.
- Implemented an unexpected exception handling mechanism which
collects information regarding the event and offers to email it to
our support team. This will assist us in resolving problems
occurring
in the wild.
- The demo database now includes some demo EMG data.
- Additional muscle images added to the hardware profile channel
pages.
|
|
Version 6.19.3840 Build 3840 08th Apr 2003
|
- Extended analysis to include FFT and PSD.
- Tests can correctly be analysed immediately after measurement
without having to close the Test Session window. Previously the
file remain locked until the window was closed, preventing analysis.
- Hardware Profiles dialog now allows the specification of the
acquisition device for customers using multiple acquisition sources.
- The patient and patient search forms are now resizable.
- Automatically checks for updates periodically, prompting the
user with new features/fixes and providing the opportunity to
download and install updates automatically. Obviously this feature
requires an internet connection.
- Periodically checks for MIE news bulletins which provide a
variety of information like new products, trade exhibitions,
training seminars, publications, etc. Naturally this feature can be
disabled if you find it irrelevant or intrusive.
- Fixed 'Syntax error in field definition' problem when exporting
to MS Excel.
|
|
Version 6.18.3300 Build 3300 7th Feb 2003
|
- Fixed intermittent crash after performing a new measurement.
- Added encyclopaedia and muscle map relating to surface EMG.
|
|
Version 6.17.3025 Build 3025 30th Jan 2003
|
- Hardware Profiles dialog now correctly populates the drop-down
lists of the Channel Summary page in a release build.
- Added an Import button to the tests tab of the patient form to allow
tests to be imported from third-party or legacy formats. Limited
import support available at the moment.
- Improved the layout of the tests tab of the patient form to
accommodate new import facility and display more tests within the
list. Additionally keyboard shortcut accelerators have been added to
the various actions available from this page.
- Entries in the test list of the test history tab of the patient
form can now be sorted by clicking on the
column headers. Initially the list is now sorted by test date with
newer tests appearing at the head of the list.
- Updated custom controls to correct visual appearance whilst
running under Windows XP - buttons now match the user's desktop
theme for example.
|
Intermittent crash after performing a new measurement.
|
Version
6.16.2770 Build 2770 18th Jan 2003
|
- Basic analysis options are now provided for DataLogger tests.
- Duplicate entries no longer appear in the analysis popup menu.
|
|
Version
6.15.2750 Build 2750 18th Jan 2003
|
- Imported data logger data is now converted to real world values
as determined by the hardware profile.
|
Initial graph zooming during analysis of real world values could
do with improving. Currently each chart is scaled to fit contents -
however this can make very small measurement changes seem rather large
at first glance.
|
Version
6.14.2740 Build 2740 18th Jan 2003
|
- Initial support for importing data logger data files complete.
|
Imported data logger data is currently only displayed in the raw
digital format. The hardware profile is not yet used to convert the
values to their real world values.
Duplicate entries appear in the popup analysis menu - one for
normal EMG tests and another for DataLogger tests.
Exporting DataLogger analysis graphs to Excel fails with 'Syntax
error in field definition' error (possibly OfficeXP specific?)
- When importing multiple data logger files within one session you
are only prompted to enter comments for the last test.
Only raw analysis of DataLogger tests is currently supported.
|
- New option to delete data logger source files upon successful
import.
|
- Selecting 'Analyse' within the 'Test Session Wizard' after
performing multiple measurements within the same test session now
correctly analyses all the tests within that session rather than
just the last test.
|
Version
6.13.2620 Build 2620 20th Dec 2002
|
- Updated versioning to be consistent with old DOS software plus
minor enhancements.
|
|
Version
1.12.2550 Build 2550 26th Nov 2002
|
- Installation script updated to install correct icon for the
application shortcut. The correct release notes are now installed. Additionally the setup script is now built
using version 8 of InstallShield Developer.
|
Test duration is not displayed on the status bar whilst conducting
a test.
|
- Windows XP manifest file added to improve
display, layout and rendering of controls when running under Windows
XP. Main custom controls updated (namely list and treelist) updated to
take this into account.
|
Other custom controls not yet updated - these will render in the
old style.
|
- DataLogger media card is now detected upon insertion.
|
Upon DataLogger media card insertion a popup explorer window may
be launched by Windows or by the card readers drivers - depending
upon the operating system, card drivers and system configuration.
This window is superfluous but as yet its creation is not blocked
programmatically, forcing the user to close the window manually.
|
- The TestSession wizard now remembers the previous values used
for the test parameters, completing the form automatically. The
clinician performing the test (testor) must be set once per session
(initally defaults to the logged in user if possible), this is then
used as a default until the software is quit. The test parameters
default to the last values used when testing the currently selected
patient. If the patient has not been tested previously, the default
parameters are used..
|
Implementation for importing DataLogger data is not yet
complete.
|
- The 'Normal EMG' and 'Data Logger' test session wizards now
display a distinctive image of the appropriate product. Additionally
the test session wizards can now be resized.
|
|
- Internal database structure updated to accommodate forthcoming
changes and features.
|
Version
1.11.2320 Build 2320 16th Nov 2002
|
- Added initial implementation for importing data from the
DataLogger unit.
|
DataLogger media card is not automatically detected upon
insertion.
|
Version
1.10.2100 Build 2100 13th Sep 2002
|
- Initial public release. Feedback welcome.
|
- Real-time display during acquisition is not customisable.
|
- Hardware profiles can now be correctly
edited and saved. Previously the profile items could not be expanded
within the tree.
|
- Event triggers during acquisition are not implemented.
|
- Hardware profiles can now be deleted.
|
- 'Rolling start' acquisition is not implemented.
|
- Added balloon help to real-time display during acquisition to
assist first time users.
|
Hardware Profiles dialog is not populating the drop-down
lists of the Channel Summary page in release builds.
|
|
|
|
|
Version
1.00.1580 Build 1580 23rd Aug 2002
|
- None - pre-release. Feedback welcome.
|
- Analysis is limited, more to come in later updates.
|
- Custom transducer classes/models cannot be created.
|
Hardware profile wizard easy channel configuration pages are not
complete. Final muscle maps are missing. Use the advanced summary
page instead.
|
- Import feature from DOS MyoDat software is not yet implemented.
|